niconiconi on Nostr: Result of the first calorimetry test run. The system's response is pretty much the ...
Result of the first calorimetry test run. The system's response is pretty much the thermal analog of a charging capacitor, with two time constants. It should be trivial to find the calorimeter's thermal resistance and capacitance by fitting the temperature output as a first-order RC network. #electronics
Published at
2025-01-18 11:40:23Event JSON
{
"id": "0942616d8cd8e6b6b29fdbb336b6a238c52054eb96d0631ad2d3672d4a809167",
"pubkey": "26fdcfc5f6ff27a9926ef372554241c70b1042094ec7749aa301091e34d17aa0",
"created_at": 1737200423,
"kind": 1,
"tags": [
[
"e",
"da6bb3acb11fb8d77d1e01912ed4c62e12182aa4977a9eec68714a626682f8fc",
"wss://relay.mostr.pub",
"reply"
],
[
"t",
"electronics"
],
[
"imeta",
"url https://misskey-taube.s3.eu-central-1.wasabisys.com/files/eb8c9b0c-bfa5-4b89-9b5a-f104c77c85be.webp",
"m image/webp"
],
[
"proxy",
"https://mk.absturztau.be/notes/a35olakckihc009w",
"activitypub"
]
],
"content": "Result of the first calorimetry test run. The system's response is pretty much the thermal analog of a charging capacitor, with two time constants. It should be trivial to find the calorimeter's thermal resistance and capacitance by fitting the temperature output as a first-order RC network. #electronics\n\nhttps://misskey-taube.s3.eu-central-1.wasabisys.com/files/eb8c9b0c-bfa5-4b89-9b5a-f104c77c85be.webp",
"sig": "faa87ffaa42aa2a750a3266ba63f58267da53e71641097011548c5ab5a360b2fb372600dad6df1400738fe7a981a4bafb836f3b224d9f8e11829180582b8f566"
}